logo
Casa > produtos >
Sensor de pressão
>
Differential Pressure Transmitter for HVAC, 4-20mA, 0.5% High Quality DP Transmitter for Water Small 0-10v Differential Pressure Sensor for air

Differential Pressure Transmitter for HVAC, 4-20mA, 0.5% High Quality DP Transmitter for Water Small 0-10v Differential Pressure Sensor for air

Detalhes do produto:
Lugar de origem: CHINA
Marca: RUIJIA
Certificação: CE
Número do modelo: RJ
Informações detalhadas
Lugar de origem:
CHINA
Marca:
RUIJIA
Certificação:
CE
Número do modelo:
RJ
Nível de precisão:
0,5%
Tópico de estoque:
M20*1.5
Faixa de medição:
0 ~ 10kpa a 2.5mpa
Sinal de saída:
4-20mA/0-5V/1-5V
Nível de proteção:
IP65
Material do diafragma:
316L Aço inoxidável
Fonte de energia:
24V DC
Temperatura do ambiente de trabalho:
0-80 ° C.
Resistente a ataques instantâneos:
Faixa de 150%
Destacar:

High Light

Destacar:

HVAC differential pressure transmitter 4-20mA

,

water DP transmitter 0.5% accuracy

,

air differential pressure sensor 0-10v

Informações de negociação
Quantidade de ordem mínima:
1
Preço:
$85-130
Detalhes da embalagem:
Embalagem de exportação padrão
Tempo de entrega:
5-8 dias de trabalho
Termos de pagamento:
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Habilidade da fonte:
1000 peças/peças por mês
Descrição do produto

Differential Pressure Transmitter for HVAC, 4-20mA, 0.5%

 

 

Integrated differential pressure transmitter, diff pressure sensor, provides 0.5% high accuracy level, IP65 protection, 4-20mA output signal, stainless steel material, anti-leakage, anti-interference, and anti-impact. Low price differential pressure transducer applies for monitoring filtration processes, measuring liquid or gas flow rates, and ensuring precise control in HVAC systems.

Measuring Range 0~50kPA,0~100kPa,0~0.6Mpa,0~1.6Mpa,0~2Mpa,0~2.5Mpa
Output Signal 4~20mA,0~5V,1~5V
Installation Method Horizontal Installation ,Vertical installation
Pressure Type Gauge Pressure ,Absolute Pressure

 

Overview

Good price HVAC differential pressure transducer is an integrated differential pressure sensor, equipped with stainless steel material, IP65 protection, 4-20mA output signal. The provided diff pressure transmitter can prevent leakage, interference and impact, suitable for industrial processes to monitor and control variables such as liquid levels, flow rates, and fluid densities.

Pressure range 0~10KPa…..35KPa...~2MPa
Allow overpressure Less than or equal to 1.5 times the rated range or 7MPa (take the minimum value)
Accuracy ±0.25% / ±0.5%
Long-term stability ±0.5%F.S/years(≤200KPa) ±0.2%F.S/years(≤2000KPa)
Zero temperature drift ±0.03%F.S/℃(≤100KPa) ±0.02%F.S/℃(>100KPa)
Full-scale temperature drift ±0.03%F.S/℃(≤100KPa) ±0.02%F.S/℃(>100KPa)
Operating temperature -20℃~80
Storage temperature -40℃~120
Power supply 15~30VDC(Intrinsically safe type powered by safety barrier)
output signal 4~20mA 0~10/20mA 0/1~5/10VDC
Pressure interface G1/4 Internal thread / 6 gas nozzle or user selectable
shell material Stainless steel 1Cr18Ni9Ti aluminum casting plastic
Diaphragm material 316L
O-ring fluororubber
cable Polyethylene
Insulation resistance 100MΩ 100VDC
Enclosure rating IP65

Specifications

  • Accuracy Level: 0.5%
  • Stock Thread: M20*1.5
  • Measuring Range: 0~10kPa to 2.5MPa
  • Output Signal: 4-20mA/0-5V/1-5V
  • Protection Level: IP65
  • Diaphragm Material: 316L Stainless Steel
  • Power Supply: 24V DC
  • Working Environment Temperature: 0-80°C
  • Resistant to Instant Strikes: 150% Range

Dimension (Unit: mm)

Differential Pressure Transmitter for HVAC, 4-20mA, 0.5% High Quality DP Transmitter for Water Small 0-10v Differential Pressure Sensor for air 0

Wiring

2 Wire Connection Method: Red Wire - 24V DC, Green Wire - Current Output

Differential Pressure Transmitter for HVAC, 4-20mA, 0.5% High Quality DP Transmitter for Water Small 0-10v Differential Pressure Sensor for air 13 Wire Connection Method:

Red Wire - 24V DC, Green Wire - Power Supply, Yellow Wire - Voltage Output

Differential Pressure Transmitter for HVAC, 4-20mA, 0.5% High Quality DP Transmitter for Water Small 0-10v Differential Pressure Sensor for air 2

 

Tips: What is a differential pressure transmitter mainly used for?

A differential pressure transmitter is a type of sensor, primarily used to measure the difference in pressure between two points in a system. It's widely employed in industrial processes to monitor and control variables such as liquid levels, flow rates, and fluid densities. The device senses the pressure variance across two ports and converts this information into an electrical signal, typically a 4-20 mA current loop or voltage output, which is proportional to the measured pressure difference.

Common applications include monitoring filtration processes, measuring liquid or gas flow rates, and ensuring precise control in HVAC systems. In the petrochemical industry, it is utilized for monitoring pressure imbalances in pipelines. The versatility of differential pressure transmitters makes them essential in various sectors, contributing to efficient and reliable process control and ensuring the safety and performance of industrial systems.